graphical user interface matlab version 7.0 Search Results


90
Cambridge Research Systems visual stimulus generator (vsg 2/5
Visual Stimulus Generator (Vsg 2/5, supplied by Cambridge Research Systems, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/visual stimulus generator (vsg 2/5/product/Cambridge Research Systems
Average 90 stars, based on 1 article reviews
visual stimulus generator (vsg 2/5 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
GraphPad Software Inc 7.0 software
7.0 Software, supplied by GraphPad Software Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/7.0 software/product/GraphPad Software Inc
Average 90 stars, based on 1 article reviews
7.0 software - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Etymotic Research Inc insert earphones er-2
Insert Earphones Er 2, supplied by Etymotic Research Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/insert earphones er-2/product/Etymotic Research Inc
Average 90 stars, based on 1 article reviews
insert earphones er-2 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Renishaw Inc system 1000
Characteristics of the five studies included in the meta-analysis
System 1000, supplied by Renishaw Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/system 1000/product/Renishaw Inc
Average 90 stars, based on 1 article reviews
system 1000 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Lambda Solutions Inc table-top dispersive raman spectrometer
Characteristics of the five studies included in the meta-analysis
Table Top Dispersive Raman Spectrometer, supplied by Lambda Solutions Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/table-top dispersive raman spectrometer/product/Lambda Solutions Inc
Average 90 stars, based on 1 article reviews
table-top dispersive raman spectrometer - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Renishaw Inc renishaw system 1000
Characteristics of the five studies included in the meta-analysis
Renishaw System 1000, supplied by Renishaw Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/renishaw system 1000/product/Renishaw Inc
Average 90 stars, based on 1 article reviews
renishaw system 1000 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Renishaw Inc customized system 1000
Characteristics of the five studies included in the meta-analysis
Customized System 1000, supplied by Renishaw Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/customized system 1000/product/Renishaw Inc
Average 90 stars, based on 1 article reviews
customized system 1000 - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Davol Inc collagen sponge scaffolds
Characteristics of the five studies included in the meta-analysis
Collagen Sponge Scaffolds, supplied by Davol Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/collagen sponge scaffolds/product/Davol Inc
Average 90 stars, based on 1 article reviews
collagen sponge scaffolds - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Tektronix inc oscilloscope tektronix tds3014b
Characteristics of the five studies included in the meta-analysis
Oscilloscope Tektronix Tds3014b, supplied by Tektronix inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/oscilloscope tektronix tds3014b/product/Tektronix inc
Average 90 stars, based on 1 article reviews
oscilloscope tektronix tds3014b - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


Characteristics of the five studies included in the meta-analysis

Journal: Translational Andrology and Urology

Article Title: Diagnostic accuracy of Raman spectroscopy for prostate cancer: a systematic review and meta-analysis

doi: 10.21037/tau-20-924

Figure Lengend Snippet: Characteristics of the five studies included in the meta-analysis

Article Snippet: Among them, five studies were selected in the final quantitative analysis by screening of the full text of the nineteen studies according to the inclusion and exclusion criteria. shows the characteristics of the 5 studies included ( 8 , 14 , 16 , 20 , 21 ). fig ft0 fig mode=article f1 fig/graphic|fig/alternatives/graphic mode="anchored" m1 Open in a separate window caption a7 PRISMA flowchart. table ft1 table-wrap mode="anchored" t5 caption a7 Study Country Total number of patients Total number of spectra (malignant/control) Sample type Type of Raman spectroscopy Main Raman algorithm type Spectral analysis Laser (nm) Total sensitivity (%) Total specificity (%) Crow 2003, ( 20 ) United Kingdom 27 456 (249/207) snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) Renishaw system 1000 PCA and LDA MATLAB (Mathwork Inc.) 832 91.6 92.8 Crow 2005, ( 16 ) United Kingdom 37 197 (77/120) snap frozen prostate tissue by TURP (stored at −80 °C) Near-infrared Raman spectroscopy PCA and LDA MATLAB 6.0 (Mathwork Inc.) 785 80 88.9 Lopes 2011, ( 8 ) Brazil N/A 105 (14/91) Snap frozen and stored in liquid nitrogen stored prostate tissue by radical prostatectomy, TURP, autopsy Table-top dispersive Raman spectrometer PCA MATLAB 7.0 (Mathwork Inc.) 830 100 100 Silveira 2014, ( 14 ) Brazil 32 152 (75/77) Snap frozen in liquid nitrogen-stored prostate tissue by surgical procedure Table-top dispersive Raman spectrometer (model Dimension P-1, Lambda solutions) Ordinary least-squares analysis MATLAB 7.0 (Mathwork Inc.) 830 73.7 75 Stone 2003, ( 21 ) United Kingdom N/A 520 (313/207) Snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) customized Renishaw system 1000 Raman micro-spectrometer PCA and LDA MATLAB (Mathwork Inc.) 830 93.3 92.2 Open in a separate window PCA, principal components analysis; LDA, linear discriminant analysis; TURP, transurethral resection of prostate. caption a8 Characteristics of the five studies included in the meta-analysis Among all included studies in the meta-analysis, three evaluated the diagnostic performance of RS in vitro , and only one study was conducted in vivo .

Techniques: Raman Spectroscopy

Characteristics of the five studies included in the meta-analysis

Journal: Translational Andrology and Urology

Article Title: Diagnostic accuracy of Raman spectroscopy for prostate cancer: a systematic review and meta-analysis

doi: 10.21037/tau-20-924

Figure Lengend Snippet: Characteristics of the five studies included in the meta-analysis

Article Snippet: Among them, five studies were selected in the final quantitative analysis by screening of the full text of the nineteen studies according to the inclusion and exclusion criteria. shows the characteristics of the 5 studies included ( 8 , 14 , 16 , 20 , 21 ). fig ft0 fig mode=article f1 fig/graphic|fig/alternatives/graphic mode="anchored" m1 Open in a separate window caption a7 PRISMA flowchart. table ft1 table-wrap mode="anchored" t5 caption a7 Study Country Total number of patients Total number of spectra (malignant/control) Sample type Type of Raman spectroscopy Main Raman algorithm type Spectral analysis Laser (nm) Total sensitivity (%) Total specificity (%) Crow 2003, ( 20 ) United Kingdom 27 456 (249/207) snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) Renishaw system 1000 PCA and LDA MATLAB (Mathwork Inc.) 832 91.6 92.8 Crow 2005, ( 16 ) United Kingdom 37 197 (77/120) snap frozen prostate tissue by TURP (stored at −80 °C) Near-infrared Raman spectroscopy PCA and LDA MATLAB 6.0 (Mathwork Inc.) 785 80 88.9 Lopes 2011, ( 8 ) Brazil N/A 105 (14/91) Snap frozen and stored in liquid nitrogen stored prostate tissue by radical prostatectomy, TURP, autopsy Table-top dispersive Raman spectrometer PCA MATLAB 7.0 (Mathwork Inc.) 830 100 100 Silveira 2014, ( 14 ) Brazil 32 152 (75/77) Snap frozen in liquid nitrogen-stored prostate tissue by surgical procedure Table-top dispersive Raman spectrometer (model Dimension P-1, Lambda solutions) Ordinary least-squares analysis MATLAB 7.0 (Mathwork Inc.) 830 73.7 75 Stone 2003, ( 21 ) United Kingdom N/A 520 (313/207) Snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) customized Renishaw system 1000 Raman micro-spectrometer PCA and LDA MATLAB (Mathwork Inc.) 830 93.3 92.2 Open in a separate window PCA, principal components analysis; LDA, linear discriminant analysis; TURP, transurethral resection of prostate. caption a8 Characteristics of the five studies included in the meta-analysis Among all included studies in the meta-analysis, three evaluated the diagnostic performance of RS in vitro , and only one study was conducted in vivo .

Techniques: Raman Spectroscopy

Characteristics of the five studies included in the meta-analysis

Journal: Translational Andrology and Urology

Article Title: Diagnostic accuracy of Raman spectroscopy for prostate cancer: a systematic review and meta-analysis

doi: 10.21037/tau-20-924

Figure Lengend Snippet: Characteristics of the five studies included in the meta-analysis

Article Snippet: Among them, five studies were selected in the final quantitative analysis by screening of the full text of the nineteen studies according to the inclusion and exclusion criteria. shows the characteristics of the 5 studies included ( 8 , 14 , 16 , 20 , 21 ). fig ft0 fig mode=article f1 fig/graphic|fig/alternatives/graphic mode="anchored" m1 Open in a separate window caption a7 PRISMA flowchart. table ft1 table-wrap mode="anchored" t5 caption a7 Study Country Total number of patients Total number of spectra (malignant/control) Sample type Type of Raman spectroscopy Main Raman algorithm type Spectral analysis Laser (nm) Total sensitivity (%) Total specificity (%) Crow 2003, ( 20 ) United Kingdom 27 456 (249/207) snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) Renishaw system 1000 PCA and LDA MATLAB (Mathwork Inc.) 832 91.6 92.8 Crow 2005, ( 16 ) United Kingdom 37 197 (77/120) snap frozen prostate tissue by TURP (stored at −80 °C) Near-infrared Raman spectroscopy PCA and LDA MATLAB 6.0 (Mathwork Inc.) 785 80 88.9 Lopes 2011, ( 8 ) Brazil N/A 105 (14/91) Snap frozen and stored in liquid nitrogen stored prostate tissue by radical prostatectomy, TURP, autopsy Table-top dispersive Raman spectrometer PCA MATLAB 7.0 (Mathwork Inc.) 830 100 100 Silveira 2014, ( 14 ) Brazil 32 152 (75/77) Snap frozen in liquid nitrogen-stored prostate tissue by surgical procedure Table-top dispersive Raman spectrometer (model Dimension P-1, Lambda solutions) Ordinary least-squares analysis MATLAB 7.0 (Mathwork Inc.) 830 73.7 75 Stone 2003, ( 21 ) United Kingdom N/A 520 (313/207) Snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) customized Renishaw system 1000 Raman micro-spectrometer PCA and LDA MATLAB (Mathwork Inc.) 830 93.3 92.2 Open in a separate window PCA, principal components analysis; LDA, linear discriminant analysis; TURP, transurethral resection of prostate. caption a8 Characteristics of the five studies included in the meta-analysis Among all included studies in the meta-analysis, three evaluated the diagnostic performance of RS in vitro , and only one study was conducted in vivo .

Techniques: Raman Spectroscopy

Characteristics of the five studies included in the meta-analysis

Journal: Translational Andrology and Urology

Article Title: Diagnostic accuracy of Raman spectroscopy for prostate cancer: a systematic review and meta-analysis

doi: 10.21037/tau-20-924

Figure Lengend Snippet: Characteristics of the five studies included in the meta-analysis

Article Snippet: Among them, five studies were selected in the final quantitative analysis by screening of the full text of the nineteen studies according to the inclusion and exclusion criteria. shows the characteristics of the 5 studies included ( 8 , 14 , 16 , 20 , 21 ). fig ft0 fig mode=article f1 fig/graphic|fig/alternatives/graphic mode="anchored" m1 Open in a separate window caption a7 PRISMA flowchart. table ft1 table-wrap mode="anchored" t5 caption a7 Study Country Total number of patients Total number of spectra (malignant/control) Sample type Type of Raman spectroscopy Main Raman algorithm type Spectral analysis Laser (nm) Total sensitivity (%) Total specificity (%) Crow 2003, ( 20 ) United Kingdom 27 456 (249/207) snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) Renishaw system 1000 PCA and LDA MATLAB (Mathwork Inc.) 832 91.6 92.8 Crow 2005, ( 16 ) United Kingdom 37 197 (77/120) snap frozen prostate tissue by TURP (stored at −80 °C) Near-infrared Raman spectroscopy PCA and LDA MATLAB 6.0 (Mathwork Inc.) 785 80 88.9 Lopes 2011, ( 8 ) Brazil N/A 105 (14/91) Snap frozen and stored in liquid nitrogen stored prostate tissue by radical prostatectomy, TURP, autopsy Table-top dispersive Raman spectrometer PCA MATLAB 7.0 (Mathwork Inc.) 830 100 100 Silveira 2014, ( 14 ) Brazil 32 152 (75/77) Snap frozen in liquid nitrogen-stored prostate tissue by surgical procedure Table-top dispersive Raman spectrometer (model Dimension P-1, Lambda solutions) Ordinary least-squares analysis MATLAB 7.0 (Mathwork Inc.) 830 73.7 75 Stone 2003, ( 21 ) United Kingdom N/A 520 (313/207) Snap frozen in liquid nitrogen-stored prostate tissue by prostate biopsy (stored at −80 °C) customized Renishaw system 1000 Raman micro-spectrometer PCA and LDA MATLAB (Mathwork Inc.) 830 93.3 92.2 Open in a separate window PCA, principal components analysis; LDA, linear discriminant analysis; TURP, transurethral resection of prostate. caption a8 Characteristics of the five studies included in the meta-analysis Among all included studies in the meta-analysis, three evaluated the diagnostic performance of RS in vitro , and only one study was conducted in vivo .

Techniques: Raman Spectroscopy